Reference · IEC 60529

IP ratings, decoded

Two digits tell you how well an enclosure keeps out fingers, tools, dust and water. This page explains every one of them, with the test behind each number.

7
levels against solids, 0 to 6
10
levels against water, 0 to 9
1976
first edition of the standard
80 °C
water in the IPX9 test
Example codes
IP54
Dust may enter, but not in an amount that interferes with operation or safety. Full protection against contact.
Water splashing against the enclosure from any direction causes no harm.
How to read a code

Four parts, two of them always there

IP stands for International Protection, often read as Ingress Protection. The code is defined in IEC 60529 and published in Europe as EN 60529. The two digits are independent: the first rates solids, the second rates water. A higher digit is not a quality score, it names a specific test the enclosure has passed.

  1. IP

    Code letters

    Always the same two letters. No hyphen follows them: “IP-67” is not a valid code.

  2. 6

    First digit: solids

    0 to 6. Protection of people against touching hazardous parts, and of the equipment against solid objects and dust.

  3. 7

    Second digit: water

    0 to 9. Protection against harmful ingress of water, from drips to hot high-pressure jets.

  4. M

    Optional letters

    An additional letter (A to D) and a supplementary letter (H, M, S, W) can follow. Most products carry none.

XAn X in place of a digit means that characteristic was not tested or is not stated. IPX7 says nothing about dust, it does not mean “no dust protection”.

Interactive decoder

Build any IP code and watch its test

Change the digits. The simulation shows what the first digit keeps out and the water test behind the second digit.

IP
6
7

IP67: dust-tight; protected against temporary immersion, 1 m for 30 minutes.

Common ratings
IP6X · Dust-tight
IPX7 · immersion · 1 m · 30 min
kept outgets inwater test
First digit · solids · 6

Dust-tight

What it means
No dust enters at all. Full protection against contact. The highest level for solids.
How it is tested
Dust chamber with talcum powder and the enclosure under vacuum, up to 8 hours. No dust may be found inside.
Read the full entry →
Second digit · water · 7

Temporary immersion

What it means
No harmful quantity of water enters when the enclosure is immersed for a limited time. It says nothing about water jets.
How it is tested
30 minutes under water, lowest point 1 m below the surface (tall enclosures: top at least 0.15 m below).
Read the full entry →

All 70 digit combinations

Rows are the first digit, columns the second. Highlighted cells are the ratings you meet most often. Click any cell to decode it.

Solids ↓ · Water →X0X1X2X3X4X5X6X7X8X9
0X
1X
2X
3X
4X
5X
6X
First digit

Protection against solid objects and dust

The first digit does two jobs at once: it keeps people away from hazardous parts and keeps solid objects out of the equipment.

The test probes, drawn to scale
  • Back of the hand · 50 mmIP1X
  • Finger · 12.5 mmIP2X
  • Tool · 2.5 mmIP3X
  • Wire · 1 mmIP4X
  • Dust · talcum powderIP5X · IP6X
Protection against solid objects and dust
IP0XNo protectionNo protection against contact or against solid objects.No test.
IP1XObjects ≥ 50 mmKeeps out large body surfaces such as the back of a hand. No protection against deliberate access with a finger.A rigid 50 mm sphere, pressed with 50 N, must not pass.
IP2XObjects ≥ 12.5 mmFinger-safe. The usual minimum for equipment indoors, for example inside control cabinets.A 12.5 mm sphere must not pass, and a jointed test finger (12 mm, 80 mm long) must stay clear of hazardous parts.
IP3XObjects ≥ 2.5 mmKeeps out tools, thick wires and similar objects.A rigid 2.5 mm rod, pressed with 3 N, must not pass.
IP4XObjects ≥ 1 mmKeeps out most wires, slender screws and small insects. Fine dust still gets in.A rigid 1 mm wire, pressed with 1 N, must not pass.
IP5XDust-protectedDust may enter, but not in an amount that interferes with operation or safety. Full protection against contact.Dust chamber with circulating talcum powder, up to 8 hours, with or without the enclosure under vacuum, depending on its type.
IP6XDust-tightNo dust enters at all. Full protection against contact. The highest level for solids.Dust chamber with talcum powder and the enclosure under vacuum, up to 8 hours. No dust may be found inside.
Second digit

Protection against water

Levels 1 to 6 build on each other. From 7 upward they do not: immersion and jets are different tests, so IPX7 or IPX8 does not include IPX5 or IPX6.

Protection against water
IPX0No protectionNo protection against water. For dry indoor locations only.No test.
IPX1Dripping waterVertically falling drops, such as condensation dripping from above, cause no harm.Drip box, 1 mm of water per minute, 10 minutes, enclosure upright on a turntable.
IPX2Dripping water, tilted 15°Dripping water causes no harm even when the enclosure is tilted up to 15° from its normal position.Drip box, 3 mm of water per minute, 2.5 minutes in each of four tilted positions.
IPX3Spraying waterWater sprayed at any angle up to 60° from the vertical causes no harm. Roughly: rain.Oscillating tube, 10 minutes, or a spray nozzle with shield: 10 l/min at 50 to 150 kPa, at least 5 minutes.
IPX4Splashing waterWater splashing against the enclosure from any direction causes no harm.Oscillating tube through almost 360°, 10 minutes, or the spray nozzle without shield, at least 5 minutes.
IPX5Water jetsA jet of water from a nozzle, from any direction, causes no harm. Roughly: hosing down.6.3 mm nozzle, 12.5 l/min, from 2.5 to 3 m, 1 minute per m² of surface and at least 3 minutes.
IPX6Powerful water jetsPowerful jets from any direction cause no harm. Roughly: heavy seas on deck or a fire hose.12.5 mm nozzle, 100 l/min, from 2.5 to 3 m, 1 minute per m² of surface and at least 3 minutes.
IPX7Temporary immersionNo harmful quantity of water enters when the enclosure is immersed for a limited time. It says nothing about water jets.30 minutes under water, lowest point 1 m below the surface (tall enclosures: top at least 0.15 m below).
IPX8Continuous immersionSuitable for continuous immersion. Depth and time are not fixed by the standard: the manufacturer must state them, and they must be more severe than for IPX7.Agreed between manufacturer and user. Always ask for the depth and the duration behind an IP68 claim.
IPX9High-pressure, high-temperature jetsWithstands close-range cleaning with hot water at high pressure, as used in food processing and vehicle washdown.80 °C water at 80 to 100 bar, 14 to 16 l/min, from 0.10 to 0.15 m, 30 seconds from each of four angles on a turntable.
Common ratings

The nine IP ratings you meet most often

What each one means in practice, where you typically find it, and where its limits are.

IP20

Decode

Finger-safe, dry rooms

Fingers cannot reach hazardous parts. No protection against water at all.

Typical uses
Power supplies, terminals and devices inside control cabinets; office and lab equipment.
Keep in mind
Needs a dry, clean environment or an enclosure around it.

IP44

Decode

Splash-proof

Keeps out objects over 1 mm and splashing water from any direction.

Typical uses
Outdoor sockets under a roof, bathroom luminaires, small motors and pumps.
Keep in mind
Not dust-protected and not for hosing down.

IP54

Decode

Dust-protected, splash-proof

Dust cannot enter in harmful amounts; splashing water causes no harm.

Typical uses
Industrial control cabinets, robot arms and controllers on the shop floor, power tools.
Keep in mind
The workhorse rating indoors. Not for water jets or permanent outdoor exposure.

IP55

Decode

Dust-protected, jet-proof

Dust-protected, and withstands water jets from any direction.

Typical uses
Outdoor enclosures, motors, charging stations, equipment that is hosed down occasionally.
Keep in mind
Some dust still gets in over time. For fine or conductive dust choose IP6X.

IP65

Decode

Dust-tight, jet-proof

No dust enters, and water jets from any direction cause no harm.

Typical uses
Sensors, operator panels, outdoor LED lighting, cameras, machine-mounted electronics.
Keep in mind
Not rated for immersion or for powerful jets.

IP66

Decode

Dust-tight, heavy weather

Dust-tight, and withstands powerful water jets: 100 litres per minute in the test.

Typical uses
Outdoor cabinets, marine and offshore equipment, mobile robots for outdoor patrols.
Keep in mind
Jets yes, immersion no: IP66 says nothing about being under water.

IP67

Decode

Dust-tight, survives a dunking

Dust-tight, and protected when immersed 1 m deep for 30 minutes.

Typical uses
M12 connectors, field sensors, smartphones, robots that cross puddles and flooded ground.
Keep in mind
Immersion is not a jet test. If it will be hosed down too, look for IP66/IP67.

IP68

Decode

Dust-tight, continuous immersion

Dust-tight, and suitable for continuous immersion under the conditions the manufacturer names.

Typical uses
Submersible pumps, underwater sensors and lights, cable glands, many smartphones.
Keep in mind
Without depth and duration the claim is incomplete: IP68 at 1.5 m for 30 minutes and IP68 at 10 m for a week are both “IP68”.

IP69/ IP69K

Decode

Dust-tight, hot high-pressure washdown

Dust-tight, and withstands 80 °C water at 80 to 100 bar from close range. Often written IP69K.

Typical uses
Food, beverage and pharmaceutical production, vehicle and construction equipment.
Keep in mind
Does not include immersion. Equipment for both carries a double rating such as IP68/IP69.
Selection help

Which IP rating do I need?

Pick the harshest condition the equipment will actually see. The result is a minimum, not a specification.

Solids and dust
Water
Minimum rating
IP54

dust-protected; protected against splashing water from any direction.

  • IP covers dust and fresh water only. Check chemicals, salt, UV, temperature and impact separately.
See it in the decoder
Common mistakes

Six things people get wrong about IP ratings

Myth

“IP68 is better than IP66 in every way.”

Fact

They are different tests. IP68 is about lying under still water, IP66 about powerful jets. A device can pass one and fail the other. Equipment that meets both is marked IP66/IP68.

Myth

“IP67 means waterproof.”

Fact

It means the enclosure passed 30 minutes at 1 m in fresh water, in new condition. The standard never uses the word waterproof.

Myth

“IPX4 means no dust protection.”

Fact

X means not tested or not stated. Zero would mean no protection. An IPX4 headphone may be quite dust-resistant, it just has no rating for it.

Myth

“An IP rating covers salt water, oil and chemicals.”

Fact

Tests use fresh water. Salt water, coolants, oils, cleaning agents and solvents attack seals differently and need their own proof.

Myth

“Once IP67, always IP67.”

Fact

The rating describes a new, correctly assembled unit. Seals age, covers get opened, cable glands loosen and impacts deform housings.

Myth

“IP69 and IP69K are the same thing.”

Fact

Almost. IP69K comes from ISO 20653 for road vehicles; IEC 60529 added the equivalent test as IPX9 in 2013. The water test is essentially the same, the standard behind it is not.

Optional letters

The letters after the digits

Rare on consumer products, more common on switchgear and machines.

Additional letter: access to hazardous parts

Used when people are better protected than the first digit says, or when the first digit is X. Example: IP1XB keeps out only 50 mm objects, but a finger still cannot touch live parts.

A
Back of the hand
50 mm sphere
B
Finger
Test finger, 12 mm × 80 mm
C
Tool
Rod, 2.5 mm × 100 mm
D
Wire
Wire, 1.0 mm × 100 mm

Supplementary letter: extra information

H
High-voltage apparatus
M
Water test done with moving parts running
S
Water test done with moving parts at standstill
W
Suitable for specified weather conditions

The letter K (IP6K9K, IPX6K) belongs to ISO 20653 for road vehicles and is not part of IEC 60529.

Limits of the code

What an IP rating does not tell you

Impact

Mechanical impact has its own code: IK00 to IK10 under IEC 62262.

Chemicals and corrosion

Salt spray, oils, coolants and cleaning agents are outside the scope.

Explosive atmospheres

IP is not explosion protection. Ex zones need ATEX or IECEx certification.

Temperature, UV, ice

Heat, cold, sunlight and icing are not tested.

Condensation

A sealed enclosure can still collect moisture from inside as it breathes with temperature.

Ageing

The test is done on a new unit. How long the seals last is a design and maintenance question.

North America

IP ratings and NEMA types

In the United States enclosures are usually classified by NEMA 250 types. The two systems are not equivalent: NEMA types also cover things like corrosion, icing and gasket ageing. The table works in one direction only. A NEMA type meets at least the IP code shown; an IP code does not earn a NEMA type.

IP ratings and NEMA types
NEMA typeMeets at leastTypical use
1IP20Indoor, general purpose
2IP22Indoor, dripping water
3RIP24Outdoor, rain and sleet
3, 3SIP55Outdoor, windblown dust and rain
4, 4XIP66Hose-down; 4X adds corrosion resistance
5IP53Indoor, settling dust
6IP67Occasional temporary submersion
6PIP68Prolonged submersion
12, 12K, 13IP54Indoor industrial: dust, drips, oil
In robotics

Why IP ratings matter for robots

A robot is an enclosure that moves. Joints, connectors and sensor windows are all places where dust and water try to get in, and the rating tells you where the machine can work: IP54 is usual for arms on a clean shop floor, IP65 and above for washdown and machine tending with coolant, IP66 or IP67 for mobile robots that patrol outdoors in rain.

Examples from our range

Ratings as stated in the product data, base configuration. The quotation confirms the exact scope.

Questions

IP ratings: frequent questions

What does IP stand for?

International Protection, as defined in IEC 60529. It is widely read as Ingress Protection, which describes the idea well: how far solids and water can get into an enclosure.

What is the difference between IP67 and IP68?

Both are dust-tight. IP67 is a fixed test: 1 m deep for 30 minutes. IP68 means continuous immersion under conditions the manufacturer specifies, which must be more severe than IP67. So IP68 is only meaningful together with a depth and a duration.

Is IP65 enough for outdoor use?

For rain, dust and occasional hosing down, yes. For storms with driving water, wave impact or pressure washing, look at IP66 or IP69. For places that can flood, IP67. Sunlight, frost and corrosion are separate questions the IP code does not answer.

What does the X in IPX7 mean?

That the first characteristic, protection against solids, was not tested or is not stated. It does not mean zero protection.

Does a higher second digit include all lower ones?

Up to 6, yes. From 7 on, no: IPX7 and IPX8 are immersion tests and IPX9 is a hot high-pressure test, and none of them automatically includes the jet tests IPX5 and IPX6. That is why you see double ratings such as IP66/IP68.

Who certifies an IP rating?

There is no central authority. The manufacturer declares the rating, based on its own tests or on a report from a test laboratory. For critical applications ask for the test report and which parts of the product it covers.

What is IP69K?

A rating from ISO 20653 for road vehicles: dust-tight and resistant to close-range jets of 80 °C water at 80 to 100 bar. IEC 60529 contains the equivalent water test as IPX9, so outside the vehicle industry the correct code is IP69.

Is the IK code part of the IP rating?

No. IK ratings (IK00 to IK10, IEC 62262) describe resistance to mechanical impact and are stated separately, for example IP66 IK10.

Standards behind this page

  • IEC 60529, edition 2.2 (2013): Degrees of protection provided by enclosures (IP Code). In Europe EN 60529, in Germany DIN EN 60529 (VDE 0470-1).
  • ISO 20653: Road vehicles, degrees of protection (IP code). Source of the K ratings such as IP69K.
  • IEC 62262: Degrees of protection against external mechanical impacts (IK code).
  • NEMA 250: Enclosures for electrical equipment, with NEMA’s comparison to IEC 60529.

This page is a plain-language summary for orientation. For design and procurement decisions the wording of the current standard applies.

Your environment

Not sure which rating your application needs?

Tell us where the robot has to work: dust, water, cleaning, temperature. We tell you which models fit and where the limits are.